System Installation
24 Adept Cobra i600/i800 Robot User’s Guide, Rev G
3.2 System Cable Diagram
Figure 3-1. iCobra System Cable Diagram
Installation Procedure
Step Step Description Part(s)
1 Connect AIB XPANEL cable to XPANEL on Interface Panel. A
2 Verify XUSR jumper plug is installed on XUSR connector. B
3 Connect Front Panel cable to Front Panel and XFP connector. C, D
4 If no T2, install XMCP jumper or T1/T2 bypass plug. Skip to 5. E, F
4a If you have T2, connect T1/T2 adapter cable to XMCP connector. G, H
5 Connect user-supplied ground. See Section 3.8 on page 34 for locations. -
6 Connect 200-240 VAC to AC Input on Interface Panel, secure with clamp. J
7 Connect 24 VDC to DC Input on Interface Panel. (May need AC cable.) K, L
8 Connect null modem serial cable to Interface Panel and serial port on PC. M